Analog Devices Inc. ADM2761E & ADM2763E RS-485 Transceivers
Analog Devices Inc. ADM2761E and ADM2763E Transceivers are 500kbps, 5.7kVRMS, signal isolated RS-485 transceivers that pass radiated emissions which test the EN 55032, Class B standard with margin. These transceivers are compliant with the RS-485 and RS-422 communication standards. The ADM2761E and ADM2763E Transceivers are optimized for low speed over long cable runs and have a maximum data rate of 500kbps. These transceivers feature an isolation barrier that provides robust system-level immunity to IEC 61000-4-x system-level Electromagnetic Compatibility (EMC) standards. The ADM2763E transceivers feature a receiver cable invert pin to quickly correct the reversed cable connection on the A and B receiver bus pins.The Analog Devices Inc. ADM2761E and ADM2763E Transceivers operate at 1.7V to 5.5V and 3.0V to 5.5V input voltage ranges on VDD1 and VDD2 supply voltages, respectively, within a -40°C to +125°C temperature range. The ADM2761E and ADM2763E Transceivers offer half-duplex and full-duplex device options in the industry standard. These transceivers come in a 16-lead, wide-body, standard SOIC_W package with 8.3mm creepage and clearance. The high differential output voltage of the transceivers makes them suitable for PROFIBUS® nodes when powered with 5V on the VDD2 supply. Applications include solar inverters, electrical test/measurement, heating/ventilation/air conditioning (HVAC) networks, industrial field buses, and building automation.
Features
- 5.7kVRMS, signal isolated RS-485 transceiver
- 1500V peak and DC working voltage to DIN V VDE 0884-11
- Low radiated emissions pass EN55032, Class B with a margin on a 2-layer PCB
- Receiver cable inversion smart feature (ADM2763E)
- Correction for reversed cable connection on A and B bus pins while maintaining full receiver fail-safe feature
- ESD protection on the RS-485 A, B, Y, and Z bus pins
- ≥±12kV IEC 61000-4-2 contact discharge
- ≥±15kV IEC 61000-4-2 air discharge
- 500kbps low-speed data rate for EMI control
- Flexible power supply inputs:
- 1.7V to 5.5V primary VDD1 supply range
- 3.0V to 5.5V isolated VDD2 supply range
- PROFIBUS compliant for 5V VDD2
- -40°C to +125°C operating temperature range
- >250kV/µs high common-mode transient immunity
- Short-circuit, open circuit, and floating input receiver fail-safe
- Supports 192 bus nodes (72kΩ receiver input impedance)
- Full hot swap support (glitch-free power-up and power-down)
- Safety and regulatory approvals (pending)
- CSA component acceptance notice 5A, DIN V VDE 0884-11, UL 1577, CQC11-471543-2012, and IEC 61010-1
- 16-lead, wide-body, SOIC_W package with 8.3mm creepage and clearance in standard pinout
Applications
- Solar inverters
- Electrical test and measurement
- Heating, Ventilation, and Air Conditioning (HVAC) networks
- Industrial field buses
- Building automation
Block Diagrams