Carlo Gavazzi RGC1P Single-Phase Solid State Relays

Carlo Gavazzi RGC1P Single-Phase Solid State Relays feature an integrated heatsink and are available in two variants: proportional switching controller types and communications interface types. The RGC1P components control the output power of 1-phase loads with an analog control input. Input types cover a wide range of current and voltage ranges. Local setting by an external potentiometer is possible. Switching modes, selectable through a front knob, allow phase angle control, full-cycle control, advanced full-cycle control specific for short wave infrared heaters, and soft starting for limiting inrush current of loads having a high-temperature coefficient. The output of the RGC1P is protected against overvoltages by utilizing an integrated varistor across the output. Two front LEDs indicate the status of the load and control.

Features

  • 1-pole, single-phase devices with integrated heat sinks
  • Selectable operation modes
  • Internal varistor protection on output
  • Integrated surge protection
  • Reverse input protection
  • DIN or panel mount
  • LED status indication
  • IP20 protection
  • Pollution degree 2
  • Overvoltage category III
  • UL 94V-0 flammability rating
  • RoHS compliant

Applications

  • Plastic machinery
    • Injection machines
    • Extrusion machines
    • PET blow molding machines
  • Packaging machinery
  • Sterilization machinery
  • Drying tunnels
  • Semiconductor manufacturing equipment 

Specifications

  • Proportional switching controller type
    • 45Hz to 65Hz operational frequency range
    • >0.7 power factor at the rated voltage
    • 6kV rated impulse withstand voltage (1.2/50µs)
    • ≤5mAAC leakage current at the rated voltage
    • Operational voltage ranges
      • 85VAC to 265VAC with an 800Vp blocking voltage
      • 190VAC to 550VAC with a 1200Vp blocking voltage
      • 410VAC to 660VAC with a 1200Vp blocking voltage
    • 250mAAC or 500mAAC minimum operational currents
    • Supply voltage ranges
      • 24VDC (-15%/+20%), 24VAC (±15%)
      • 90VAC to 250VAC
    • Temperature ranges
      • -40°C to +70°C operating
      • -40°C to +100°C storage
  • Communications interface type
    • 600VAC rated voltage (42VAC to 660VAC range) at 50/60Hz
    • >0.9 power factor
    • 6kV rated impulse withstand voltage (1.2/50µs)
    • <5mAAC leakage current at the rated voltage
    • 42VAC to 660VAC operational voltage range
    • Operational current ranges
      • 300mAAC to 50AAC
      • 500mAAC to 90AAC
    • 50/60Hz operational frequency range
    • 1200Vp blocking voltage
    • 4VDC to 32VDC control voltage range
    • 3.8VDC pick-up voltage
    • 1VDC drop-out voltage
    • 32VDC maximum reverse voltage
    • -20°C to +65°C temperature range
Publicado: 2022-07-06 | Actualizado: 2022-07-21